Arc Blast Damaged Westinghouse PC32000 Molded Case Circuit Breaker

December 29, 2011 Electrical news in milwaukee,Wisconsin, United States of America

If you want to see a good picture of a large circuit breaker that has been damaged by an arc blast, look at the pictures with this blog. The breaker was a Westinghouse PC32000 molded case circuit...




FOR IMMEDIATE RELEASE
milwaukee, Wisconsin, United States of America (Free-Press-Release.com) December 29, 2011 --

1 2
Arc Blast Damaged Westinghouse PC32000 Molded Case Circuit Breaker Arc Blast Damaged Westinghouse PC32000 Molded Case Circuit Breaker

Welcome visit Our WebSite:

http://www.circuitbreakersblog.com/2011/12/arc-blast-damaged-westinghouse-pc32000-molded-case-circuit-breaker/

If you want to see a good picture of a large circuit breaker that has been damaged by an arc blast, look at the pictures with this blog. The breaker was a Westinghouse PC32000 molded case circuit breaker. It was a 2000 amp circuit breaker that failed to interrupt a fault and blasted the inside of the breaker until it actually blew a hole through the side of the circuit breaker frame. If you look closely, you will see where a MIDWEST switchgear service technician actually stuck a screwdriver through the hole. The close up picture shows the hole and shows the extensive arcing damage to the moveable arcing and main contacts. The phase barriers, arc chutes, pretty much the whole Westinghouse PC32000 circuit breaker, was arc blasted beyond repair. One picture shows the destroyed circuit breaker next to a MIDWEST inventory stock PC32000 circuit breaker. This is a tough Westinghouse molded case circuit breaker. It wouldn’t make any difference whether the breaker was Square D or GE General Electric. If the breaker contacts begin to open, but fail to interrupt the current, arc damage will quickly occur. If the breaker is trying to interrupt fault current, extensive arc damage occurs very fast and will quickly expand into a phase to phase fault with catastrophic destruction. The arcing fault may explode outside the case of the circuit breaker. This is one of the reasons for wearing protective clothing and following safe work practices when operation circuit breakers. Bad things can happen very fast. Too fast for you to get out of the way. We suggest being paranoid about safety when working around electrical power equipment.

More information can be found online at http://www.circuitbreakersblog.com/2011/12/arc-blast-damaged-westinghouse-pc32000-molded-case-circuit-breaker/


free-press-release.com arc blast     Arc Blast Damaged Breaker     arcing damage     Damaged Circuit Breaker     Phase To Phase Fault     protective clothing     westinghouse circuit breakers     Westinghouse PC32000

Share |


Contact Information


People who viewed this press release also interested in the following topics: arc chutes, Damaged Circuit Breaker, printing press damage, large breakers, and molded case circuit breaker inside view.




Upcoming Trade ShowNew Press NewsNew Exclusive News More Press News

  • Asian Elenex 2012
    Asian Elenex 2012 When: 2012.06.01~2012.06.01
    Where: Hong Kong,
    Industry: Electrical Equipment & Supplies
  • Total Processing and Packaging When: 2012.06.04~2012.06.06
    Where: Birmingham,United Kingdom
    Industry: Electrical Equipment & Supplies
  • Eliaden When: 2012.06.04~2012.06.07
    Where: Lillestrom,Norway
    Industry: Electrical Equipment & Supplies


  • Post your news to the World.See you news here immediately. It's easy and free!
    Create free account or Login.