LIGHTNING CONSULTING REQUIRES TWO SPECIFIC AUDITS OF THE SITE LOCATION TO...
LIGHTNING CONSULTING REQUIRES TWO SPECIFIC AUDITS OF THE SITE LOCATION TO ENSURE THAT LIGHTNING STRIKE ENERGY DOES NOT CAUSE DAMAGE 
May 1, 2011 Electronics news in Castle Rock,Colorado, United States of America
All electrical equipment damage from lightning may be placed into two categories; improper site grounding resulting in lightning induced GPR, and failure to electrically protect equipment from surge.
FOR IMMEDIATE RELEASE
Castle Rock,
Colorado,
United States of America
(Free-Press-Release.com) May 1, 2011 --
There is not one national code available today that recommends protection of equipment from lightning strike energy. IEEE is finally completing IEEE Std. 1692-2011 this year that will recommend this type of protection for the very first time. The seed document that was used to develop this new Std. is "Guide for Protection of Equipment and Personnel from Lightning", in the ASCE Journal of Performance of Constructed Facilities, issued August issue 2002 and authored by Duckworth.
LIGHTNING CONSULTING REQUIRES TWO SPECIFIC AUDITS OF THE SITE LOCATION TO ENSURE THAT LIGHTNING STRIKE ENERGY DOES NOT CAUSE DAMAGE
Welcome visit Our WebSite:
http://www.lightning-protection-institute.com Current sources widely thought of, as lightning consulting sources, provide little or no lightning protection recommendations, and lightning induced GPR is just not mentioned. Some of these sources that are not providing the necessary lightning consulting design against lightning induced GPR include NEC, NESC, NFPA 780, and Motorola’s Standards and Guidelines for Communication Sites (R56 Issue B).
Lightning consulting must first provide a proper grounding audit of the site. A proper grounding audit must include an evaluation of the conductivity of the soil so that a grounding system can be designed to dissapate ligfhtning currents. Lightning currents contain high frequencies and ground rods are not very effective because these currents travel better on the surface of the earth. Thus, horizontal radials that act like one side of a capacitor with the earth as the other capacitor plate is the answer. Good lightning consulting must attempt to reduce the lightning induced GPR at the site to as low a value as possible with capacitive radial grounding design.
Second, lightning consulting must include an audit of the electrical protection of the equipment building. This audit must include the evaluation of single point grounding of equipment, HALO grounding of metal objects to minimize electromagnetic radiation, the use of shunting and isolation devices, and the grounding of the equipment building.
LPGI & Affiliates has over 140 years of total combined engineering experience in all types of grounding and electrical protection. We can minimize and may even eliminate that next lightning strike's damage that we have seen as high as $100K in equipment damage with one to two weeks of down time for repair.
Our consulting fee with AutoCAD Drawings and a step by step recommendations on the resolution of your equipment lightning damage will be a small fraction of the cost of your next lightning strike. Our record is long and our results are verified by our many and happy clients.
More information can be found online at http://www.lightning-protection-institute.com
lightning audit lightning consulting LIGHTNING GROUNDING lightning grounding audit Lightning Protection
People who viewed this press release also interested in the following topics: lightning institute.
Where: Rimini,Italy
Industry: Electronic Components & Supplies
Where: Santa Clara,United States
Industry: Electronic Components & Supplies
Where: Nuremberg,Germany
Industry: Electronic Components & Supplies
Post your news to the World.See you news here immediately. It's easy and free!
Create free account or Login.